Feature:
1. Hall‑type current conversion, which can withstand 30 times the nominal input, prevents instantaneous high current access and burns out the internal components of the sensor. The measurement circuit is isolated from the incoming
2. Isolate the detection and the output , effectively filter the noise in the , which will greatly improve the ‑to‑noise ratio and stability of the product, and effectively enhance the product\'s anti‑interference ability
3. The primary and secondary sides of the hole current transmitter are highly insulated and isolated, which bring high accuracy, small size, low power consumption, wide frequency response, and anti‑interference
4. No insertion loss because of erforated input, fixed with standard rail and flat screws, easy to install
5. Especially suitable for load current intelligent monitoring systems such as generators, motors, intelligent low‑voltage power distribution cabinets, conditioners, fans, street lamps, power grid monitoring, motor monitoring, railway system monitoring industries
Specification:
Item Type: AC Current Transmitter
Material: ABS
Power Supply: DC24V
Installation : Standard rail + flat screw fixation
Product Use: Used to measure AC current, especially for power frequency 50Hz sine AC current
Rated Current: AC0-100A
Rated Output: DC4-20mA
Load Capacity: Voltage Output: 5mA; Current Output: 6V
Accuracy: 0.5%
Overload Capacity: 30 Times the nominal input
Isolation withstand Voltage: 3KV/50Hz, 1Min
Offset Voltage: ≤10mV
Temperature Drift: ≤500PPM/℃
Linearity: 0.1%
Frequency Bandwidth: 20-5KHz
Current Consumption: <15mA+ output current
Response Time: <200ms
Working Temperature: -109℃~+70℃
Storage Temperature: 25℃~85℃
Package List:
1 x AC Current Transmitter
Note:
Please do not use 250ohm or 500ohm to connect 4‑20mA output version of the transmitter to get 0‑5V or 0‑10V, this is a completely wrong , you cannot get 0‑5V or 0‑10V , and it will make transmit becomes overheated or damaged.